Skip to product information
1 of 9

Datascope CS300 Automated Counterpulsation Balloon Pump 0998-00-3023-55

Datascope CS300 Automated Counterpulsation Balloon Pump 0998-00-3023-55

CS300 IABP

The Maquet Datascope CS300 IABP with IntelliSense combines fiber-optic speed with automatic in vivo calibration. The result is a faster time for therapy, faster signal acquisition, and faster adaptation to rate and rhythm changes. Maquet has the only fiber-optic IABP and catheter system that automatically calibrates in the patient after insertion and automatically recalibrates in vivo every two hours or sooner should the patient or environmental conditions change.

The Datascope CS300 IABP with IntelliSense software is designed to emulate an experienced user, allowing you more time to focus on your patient. This sophisticated algorithm automatically selects the best lead and trigger source, sets optimal inflation and deflation timing, and still allows the clinician the ability to fine-tune deflation timing. The Maquet IABP quickly adapts to rate or rhythm changes in order to optimize augmentation and support during diastole. 

The CS300 with intelliSense is designed to emulate an experienced user, allowing the clinician more time to focus on the patient. The CS300 regularly examines key landmarks on the ECG and arterial pressure waveform to determine optimal timing. It then quickly adapts to rate or rhythm changes instead of imposing fixed timing rules.

Features:

  • Faster inflation and deflation speed
  • CS300 has true one-button start-up
  • Automatically calibrates the fiber-optic pressure sensor in the patient and recalibrates every 2 hours or sooner should patient or environmental conditions change
  • Automatically evaluates and selects the best lead and trigger source
  • Automatically sets optimal timing
  • Automatically adjusts to changes in patient conditions without clinician intervention
  • A Maquet fiber-optic IAB catheter
  • Conventional fluid-filled IAB catheters

Trigger

  • ECG Trigger: Threshold dynamically adjusted by the system for high sensitivity and selectivity of the R-wave detection; Minimum = 120µV ± 20µV at a normal gain; 40µV at max. gain
  • Pressure Trigger: The default trigger threshold is automatically adjusted to 38% of the systolic pulse height; 7 mm minimum
  • Manual threshold mode: User-adjustable between 7 and 30 mmHg ± 3 mmHg
  • Pacer A Trigger: R-wave detection (as above) except pacer blanking is extended to 100 ms
  • Pacer V/A-V Trigger: V Pacer: fixed at a rate up to 185 bpm (no demand pacing)
  • A-V Pacer: fixed at a rate up to 125 bpm (no demand pacing) with A-V intervals between 80-224 ms

ECG

  • ECG Leads: In Auto Operation Mode: I, II, III, External In Semi-Auto Mode: I, II, III, AVR, AVL, AVF, V, External (12 lead compatibility)
  • ECG Gain (default): 1 V output per 1 mV input ±5% (waveform automatically scaled to occupy ECG display window)
  • Gain (variable): 0.15 to 3.0 cm/mV ±20% (autoscaling disabled)
  • Frequency Response: 0.5-12 Hz (display); 0.5-135 Hz (Output to External Monitor)
  • Defibrillator Protection: Discharge level = 360 J (trace returns to the screen in 5-sec max)
  • ESIS: Automatic suppression with internal ECG amplifier
The Unit powers on and complete self test. The unit is in Excellent Condition.
Our team of product experts ensures that each system is in excellent condition and produces stunning images when tested with a telescope.
Contact us today to learn more and get a personalized estimate for your needs.
We are here to help you make the most informed decision for your medical equipment purchases in your budget. 
View full details

GET IN TOUCH